General

  • The perfect "stand-by boiler"
  • Start-up in 8-10 minutes
  • Two-drum cylindrical water tube boiler
  • Standard preassembled modules
  • Top fired compact design
  • Membrane wall design
  • Made of mild carbon steel with elevated temperature properties
  • Integrated burner for Natural gas and Fuel Oil
  • Refractory is reduced to a protective layer at the bottom of the furnace
  • Designed according to new PED/EN regulations

 

Design data

Heat capacity: 8 - 38.8 MW
Steam capacity: 12 - 60 t/h
Design pressure: up to 18 bar(g)
Steam temperature:

from saturated up to

290 ºC

Efficiency (DIN 1942): 83 - 95%

 

Capacity, Fuel economy, Dimensions & Weight

 

 

 

 

 

Steam capacity          Oil-firing

Height "K" (incl. retraction of burner lance) *

Diameter "D" (incl. insulation) *

Height "H" *

Width "B"

Boiler dry weight

Boiler operation weight

kg/h

mm

mm

mm

mm

ton

ton

12,500

8,100

2,670

5,760

4,100

18.7

25.4

16,000

8,200

3,070

5,760

4,450

23.2

32.1

20,000

9,100

3,220

6,110

4,700

26.5

36.7

25,000

9,900

3,320

6,960

4,900

29.9

41.1

30,000

10,200

3,570

7,160

5,250

34.6

47.8

35,000

10,050

3,870

7,010

5,650

39.7

55.1

40,000

10,650

3,870

7,410

5,750

41.9

57.8

45,000

10,650

4,270

7,360

6,250

48.4

67.7

55,000

10,900

4,520

7,410

6,600

56.0

78.0

 

* Dimension of boiler pending final design with regards to NOx requirements, addition of superheater

and/or economizer.

 