General

  • Standard medium heat recovery units for diesel and gas engine plants
  • For CHP and Fuel Oil heating/own consumption (saturated steam or hot-water) applications
  • Smoke tube (shell & tube) type simple design
  • UNEX H is a natural circulation boiler for steam generation with integrated steam space
  • UNEX HW is a hot-water boiler for forced circulated water heating
  • Vertical and horizontal layout solutions are available
  • Vibration-considered robust construction
  • Relative large water volume allows stabile output
  • Below design data is typical data with standard execution.
  • Special solutions considered on case-by-case basis


Design data


Engine output: No limits, depending on engine
Engine fuel type: Light oil, liquid biofuel, heavy fuel oil, natural gas
Exhaust gas inlet temperature: < 530 °C
Exhaust gas flow No limits
Operating pressure: < 20 bar(g)
Steam temperature Saturated
Typical pinch point: > 25 ºC